Standard 3m Method Anechoic Chamber

0
614

Designed for civilian EMC testing (radiated emissions and immunity), with typical technical parameters below: 

Key Structural Parameters​

Test Distance: 3m (EUT to antenna)
Internal Dimensions: 
Length: ~9m (meets test distance and quiet zone requirements)
Width: ~6m (ensures quiet zone integrity)
Height: ~6m (accommodates antenna movement and quiet zone)
Absorbing Materials: 
Walls/Ceiling: Carbon-loaded pyramidal/foam absorbers (0.3–0.45m height), covering 30 MHz–18 GHz (extendable to 40 GHz)
Floor: Metallic ground plane (galvanized steel/aluminum), per CISPR 16-1-4
Shielded Door: Double-layer design, ≥100 dB shielding (30 MHz–18 GHz; optional 40 GHz)

Critical Performance Metrics

Shielding Effectiveness: 
Low Frequency (14 kHz–1 MHz): ≥80 dB
High Frequency (1 MHz–18 GHz): ≥100 dB (typical 120 dB)
Grounding Resistance: 
Standard: IEC 60364-6 (GB/T 16895.23)
Requirement: ≤ 4Ω
Insulation Resistance    : 
Standard: IEC 60364-6 (GB/T 16895.23)
Requirement: ≤ 2 MΩ
Quiet Zone: Dimensions: Approximately 1.5 meters or 2 meters in diameter and height (at 3 meters from the antenna)
Normalized Site Attenuation (NSA): 
Compliance Standards: CISPR 16-1-4 (GB/T 6113.104), ANSI C63.4
Deviation: Within ±4 dB (30 MHz–1 GHz)
Site Voltage Standing Wave Ratio (SVSWR): 
Compliance Standards: CISPR 16-1-4 (GB/T 6113.104), ANSI C63.4
Requirement: ≤ 6 dB
Field Uniformity: 
Applicable Standard: IEC 61000-4-3 (GB/T 17626.3, applicable only for radiated immunity testing)
Uniform Area: Field strength variation ≤ 6 dB within a 1.5m × 1.5m area (80 MHz–6 GHz)
Influence Assessment of Radiated Emission Test Table: 
Compliance Standards: CISPR 16-1-4, ANSI C63.4
Requirement: The influence assessment results of the radiated emission test table must be incorporated into the uncertainty evaluation of radiated emission measurements
Ambient Noise Level: At least 6 dB below the EMC product standard limits

Antenna & Turntable System

Antenna Types: Dual-polarized (>30 MHz), 9 kHz–40 GHz coverage
Turntable: 
Diameter: 2–3m, 500 kg–1 ton/m² load capacity
Accuracy: ±1°
Antenna Tower: 1–4m height adjustment, ±0.5 cm precision

Compliance Standards

Radiated Emissions: CISPR 32 (GB/T 9254.1), FCC Part 15, EN 55032
Radiated Immunity: CISPR 35 (GB/T 9254.2), EN 55032

Auxiliary Systems

Power Supply & Filtering: 
Power: Independent filtered power supply system providing clean power
Signal line filtering: All feedthrough interfaces shall be equipped with RF filters
Environmental Control: 
Temperature: 20~25℃ (±2℃)
Humidity: 30%~70% RH (anti-condensation)
Safety Systems: 
Emergency stop button, smoke alarm, fire suppression system
RF radiation safety monitoring (compliant with occupational health standards)

Search
Werbung
Categories
Read More
Other
Trusted Super Visa Insurance in Calgary
Secure the right protection for your family visit with Super Visa Insurance in Calgary from...
By Supervisa Insurance 2026-08-19 13:50:38 0 98
Other
Iconoclad Salt Lake City and the Best Fashion Finds for Every Style
Introduction to Iconoclad Salt Lake City Fashion is more than simply choosing something to wear....
By Luca Phillips 2026-08-19 15:52:19 0 87
Other
Legal Process Outsourcing Market Forecast: Industry Segmentation, Trends, and Future Growth
Market Overview The Legal Process Outsourcing Market is experiencing rapid expansion as...
By Preeti Mmr 2026-08-19 15:46:27 0 84
Other
Portable Collaborative Robot Systems Market Value to Touch $11.7B by 2036
August 19, 2026 — The global Portable Collaborative Robot Systems Market is...
By Shahir bnsode 2026-08-19 13:35:13 0 50
Other
Machine Vision Camera Market Segmentation & Forecast : Share, Size, and Growth Insights
" According to the latest report published by Data Bridge Market Research, the Machine...
By Akash Motar 2026-08-19 14:00:45 0 71