Full automation of the instrument and selection of a faster translation stage would allow for the measurement of BCS specimens within an intraoperative time scale (20 minutes). This study demonstrates that the TIR-AF Raman microscope represents a feasible step towards the development of a technique for intraoperative assessment of large WLE within intraoperative timescales.We present a SMART injector with two parallel common-path optical coherence tomography fibers to enable angle measurements and injection depth corrections for oblique subretinal injection. The two optical fibers are attached to opposite sides of a 33 G needle with known offsets and designed to pass through a 23 G trocar that has an inner diameter of 0.65 mm. By attaching a SMART system to a rotational stage, the measured angles are calibrated for minimal error from reference angles. A commercial eye model was used to evaluate the control performance, and injection experiments were performed on a phantom made of agarose gel and a porcine eye.Tissue oximetry with near-infrared spectroscopy (NIRS) is a technique for the measurement of absolute tissue oxygen saturation (StO2). Offering a real-time and non-invasive assessment of brain oxygenation and haemodynamics, StO2 has potential to be used for the assessment of newborn brain injury. https://www.selleckchem.com/products/at13387.html Multiple algorithms have been developed to measure StO2, however, issues with low measurement accuracy or extracranial tissue signal contamination remain. In this work, we present a novel algorithm to recover StO2 in the neonate, broadband multidistance oximetry (BRUNO), based on a measurement of the gradient of attenuation against distance measured with broadband NIRS. The performance of the algorithm was compared to two other published algorithms, broadband fitting (BF) and spatially resolved spectroscopy (SRS). The median error when recovering StO2 in light transport simulations on a neonatal head mesh was 0.4% with BRUNO, 4.2% with BF and 9.5% with SRS. BRUNO was more sensitive to brain tissue oxygenation changes, shown in layered head model simulations. Comparison of algorithm performance during full oxygenation-deoxygenation cycles in a homogeneous dynamic blood phantom showed significant differences in the dynamic range of the algorithms; BRUNO recovered StO2 over 0-100%, BF over 0-90% and SRS over 39-80%. Recovering StO2 from data collected in a neonate treated at the neonatal intensive care showed different baseline values; mean StO2 was 64.9% with BRUNO, 67.2% with BF and 73.2% with SRS. These findings highlight the effect of StO2 algorithm selection on oxygenation recovery; applying BRUNO in the clinical care setting could reveal further insight into complex haemodynamic processes occurring during neonatal brain injury.Precise control of the thermal damage area is the key issue during thermal therapy, which can be achieved by manipulating the light propagation in biological tissue. In the present work, a method is proposed to increase the uniformity of the specific absorption rate (SAR) distribution in tumors during laser-induced thermal therapy, which is proved to be effective in reducing the thermal damage of healthy tissue. In addition, a better way of manipulating light propagation in biological tissue is explored. It is found that the anisotropic scattering characteristics of nanoparticles are strongly dependent on their shapes, sizes, orientations, and incident wavelengths, which will strongly affect the light propagation in nanoparticle embedded biological tissue. Therefore, to obtain a better outcome from photothermal therapy, the scattering properties of nanoparticles are very important factors that need to be taken into consideration, along with the absorption efficiency. Further investigation finds that nanoparticles that predominantly scatter to the forward direction are favorable in obtaining a larger penetration depth of light, which will improve the uniformity of SAR and temperature distributions. This paper is meaningful for the application of nanoparticle-assisted laser-induced thermal therapy.The goal of this study is a comparative analysis of the efficiency of the PDT protocols for CT26 tumor model treatment in Balb/c **** employing red and blue light with both topical and intravenous administration of chlorin-based photosensitizers (PSs). The considered protocols include the doses of 250 J/cm2 delivered at 660 nm, 200 J/cm2 delivered at 405 nm, and 250 J/cm2 delivered at both wavelengths with equal energy density contribution. Dual-wavelength fluorescence imaging was employed to estimate both photobleaching efficiency, typical photobleaching rates and the procedure impact depth, while optical coherence tomography with angiography modality (OCT-A) was employed to monitor the tumor vasculature response for up to 7 days after the procedure with subsequent histology inspection. Red light or dual-wavelength PDT regimes with intravenous PS injection were demonstrated to provide the most pronounced tumor response among all the considered cases. On the contrary, blue light regimes were demonstrated to be most efficient among topical application and irradiation only regimes. Tumor size dynamics for different groups is in good agreement with the tumor response predictions based on OCT-A taken in 24h after exposure and the results of histology analysis performed in 7 days after the exposure.In vivo Raman spectroscopy has been utilized for the non-invasive, non-destructive assessment of tissue pathophysiology for a variety of applications largely through the use of fiber optic probes to interface with samples of interest. Fiber optic probes can be designed to optimize the collection of Raman-scattered photons from application-dependent depths, and this critical consideration should be addressed when planning a study. Herein we investigate four distinct probe geometries for sensitivity to superficial and deep signals through a Monte Carlo model that incorporates Raman scattering and fluorescence. Experimental validation using biological tissues was performed to accurately recapitulate in vivo scenarios. Testing in biological tissues agreed with modeled results and revealed that microlens designs had slightly enhanced performance at shallow depths ( less then 1 mm), whereas all of the beampath-modified designs yielded more signal from deep within tissue. Simulation based on fluence maps generated using ray-tracing in the absence of optical scattering had drastically different results as a function of depth for each probe compared to the biological simulation.
Full automation of the instrument and selection of a faster translation stage would allow for the measurement of BCS specimens within an intraoperative time scale (20 minutes). This study demonstrates that the TIR-AF Raman microscope represents a feasible step towards the development of a technique for intraoperative assessment of large WLE within intraoperative timescales.We present a SMART injector with two parallel common-path optical coherence tomography fibers to enable angle measurements and injection depth corrections for oblique subretinal injection. The two optical fibers are attached to opposite sides of a 33 G needle with known offsets and designed to pass through a 23 G trocar that has an inner diameter of 0.65 mm. By attaching a SMART system to a rotational stage, the measured angles are calibrated for minimal error from reference angles. A commercial eye model was used to evaluate the control performance, and injection experiments were performed on a phantom made of agarose gel and a porcine eye.Tissue oximetry with near-infrared spectroscopy (NIRS) is a technique for the measurement of absolute tissue oxygen saturation (StO2). Offering a real-time and non-invasive assessment of brain oxygenation and haemodynamics, StO2 has potential to be used for the assessment of newborn brain injury. https://www.selleckchem.com/products/at13387.html Multiple algorithms have been developed to measure StO2, however, issues with low measurement accuracy or extracranial tissue signal contamination remain. In this work, we present a novel algorithm to recover StO2 in the neonate, broadband multidistance oximetry (BRUNO), based on a measurement of the gradient of attenuation against distance measured with broadband NIRS. The performance of the algorithm was compared to two other published algorithms, broadband fitting (BF) and spatially resolved spectroscopy (SRS). The median error when recovering StO2 in light transport simulations on a neonatal head mesh was 0.4% with BRUNO, 4.2% with BF and 9.5% with SRS. BRUNO was more sensitive to brain tissue oxygenation changes, shown in layered head model simulations. Comparison of algorithm performance during full oxygenation-deoxygenation cycles in a homogeneous dynamic blood phantom showed significant differences in the dynamic range of the algorithms; BRUNO recovered StO2 over 0-100%, BF over 0-90% and SRS over 39-80%. Recovering StO2 from data collected in a neonate treated at the neonatal intensive care showed different baseline values; mean StO2 was 64.9% with BRUNO, 67.2% with BF and 73.2% with SRS. These findings highlight the effect of StO2 algorithm selection on oxygenation recovery; applying BRUNO in the clinical care setting could reveal further insight into complex haemodynamic processes occurring during neonatal brain injury.Precise control of the thermal damage area is the key issue during thermal therapy, which can be achieved by manipulating the light propagation in biological tissue. In the present work, a method is proposed to increase the uniformity of the specific absorption rate (SAR) distribution in tumors during laser-induced thermal therapy, which is proved to be effective in reducing the thermal damage of healthy tissue. In addition, a better way of manipulating light propagation in biological tissue is explored. It is found that the anisotropic scattering characteristics of nanoparticles are strongly dependent on their shapes, sizes, orientations, and incident wavelengths, which will strongly affect the light propagation in nanoparticle embedded biological tissue. Therefore, to obtain a better outcome from photothermal therapy, the scattering properties of nanoparticles are very important factors that need to be taken into consideration, along with the absorption efficiency. Further investigation finds that nanoparticles that predominantly scatter to the forward direction are favorable in obtaining a larger penetration depth of light, which will improve the uniformity of SAR and temperature distributions. This paper is meaningful for the application of nanoparticle-assisted laser-induced thermal therapy.The goal of this study is a comparative analysis of the efficiency of the PDT protocols for CT26 tumor model treatment in Balb/c mice employing red and blue light with both topical and intravenous administration of chlorin-based photosensitizers (PSs). The considered protocols include the doses of 250 J/cm2 delivered at 660 nm, 200 J/cm2 delivered at 405 nm, and 250 J/cm2 delivered at both wavelengths with equal energy density contribution. Dual-wavelength fluorescence imaging was employed to estimate both photobleaching efficiency, typical photobleaching rates and the procedure impact depth, while optical coherence tomography with angiography modality (OCT-A) was employed to monitor the tumor vasculature response for up to 7 days after the procedure with subsequent histology inspection. Red light or dual-wavelength PDT regimes with intravenous PS injection were demonstrated to provide the most pronounced tumor response among all the considered cases. On the contrary, blue light regimes were demonstrated to be most efficient among topical application and irradiation only regimes. Tumor size dynamics for different groups is in good agreement with the tumor response predictions based on OCT-A taken in 24h after exposure and the results of histology analysis performed in 7 days after the exposure.In vivo Raman spectroscopy has been utilized for the non-invasive, non-destructive assessment of tissue pathophysiology for a variety of applications largely through the use of fiber optic probes to interface with samples of interest. Fiber optic probes can be designed to optimize the collection of Raman-scattered photons from application-dependent depths, and this critical consideration should be addressed when planning a study. Herein we investigate four distinct probe geometries for sensitivity to superficial and deep signals through a Monte Carlo model that incorporates Raman scattering and fluorescence. Experimental validation using biological tissues was performed to accurately recapitulate in vivo scenarios. Testing in biological tissues agreed with modeled results and revealed that microlens designs had slightly enhanced performance at shallow depths ( less then 1 mm), whereas all of the beampath-modified designs yielded more signal from deep within tissue. Simulation based on fluence maps generated using ray-tracing in the absence of optical scattering had drastically different results as a function of depth for each probe compared to the biological simulation.
0 Comments 0 Shares 24 Views 0 Reviews
Sponsored