Ophiopogonis radix and Liriopes radix are well known for the treatment of dry coughs and phthisis. Liriopes radix is occasionally used as a substitute for Ophiopogonis radix in various prescriptions due to the extremely similar pharmacological activities and clinical efficacies, but they are regarded as two different remedies in the Chinese Pharmacopoeia. Accordingly, the establishment of a reliable analytical approach for the discrimination and quality evaluation of Ophiopogonis and Liriopes is required.

To establish a simple, accurate, and reliable method that can simultaneously determine multiple components in Ophiopogonis radix and Liriopes radix. To comprehensively compare the chemical compositions of the two herbs and find markers for discrimination and quality assessments.

An HPLC-ESI-triple quadrupole (QQQ)-MS/MS method was developed for simultaneous characterization and quantification of chemical components in the two herbs. The results were further analyzed by PLS discriminant analysis to provadix by using HPLC-QQQ-MS/MS in positive ion mode, as well as the quality control study.
Soleris®Enterobacteriaceae is a growth-based, automated method for detection of Enterobacteriaceae in food.

A study was conducted to validate the Soleris method for detection of Enterobacteriaceae in select foods (pasteurized milk, yogurt, mozzarella cheese, ice cream, dried milk, pasteurized liquid egg, frozen cooked chicken, deli ham, lettuce, and dry dog food) at a threshold of ≥ 10 CFU/g of product.

Inclusivity and exclusivity of the Soleris method were assessed by testing 55 and 38 target and non-target bacterial strains, respectively. Matrix testing was performed with one naturally contaminated and nine inoculated foods. Efficacy of the Soleris method was compared to that of the ISO 21528-22017 direct plating reference method using probability of detection analysis. Independent laboratory testing was conducted to verify method performance in two matrixes (yogurt and deli ham). Method robustness, stability, and lot-to-lot consistency of the Soleris reagents were also assessed.

Inclusivity of the Soleris test was 91% and exclusivity was 100%. In matrix testing, there were no significant differences in the number of positive results obtained with the Soleris and reference methods for any of the matrixes examined. Overall, of 370 test portions, there were 176 positive results by the Soleris method and 177 positive results by the reference procedure.

Soleris Enterobacteriaceae is an effective method for detection of Enterobacteriaceae in the foods evaluated, with performance equivalent to that of the ISO 21528-22017 reference method.

The Soleris method offers the advantages of labor savings and results within 18 h.
The Soleris method offers the advantages of labor savings and results within 18 h.
Duloxetine hydrochloride (DUL) is a drug used to treat depression and anxiety. 1-Naphthol is a potential toxic impurity of DUL, as it causes hepatotoxicity in humans, and it is harmful to aquatic life.

Three simple, selective, rapid, accurate and precise methods were developed and validated according to International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision and selectivity for analysis of duloxetine hydrochloride (DUL) in the presence of its potential toxic impurity 1-Naphthol in different laboratory-prepared mixtures and pharmaceutical formulations.

Method (A) is the first derivative of the ratio spectra spectrophotometric (1DD) method which allows determination of DUL at 251 nm and 1-Naphthol at 305.2 nm without interference from each other. https://www.selleckchem.com/products/s-2-hydroxysuccinic-acid.html Method B (dual wavelength) means that two different wavelengths were chosen to each drug, where the absorbance difference at these two wavelengths is equal to zero to the second drug. The chosen two wavelengths for DUL were 221.4 nm and 235.6, where the absorbance difference for 1-naphthol at these two wavelengths was equal to zero. While the chosen wavelengths for 1-naphthol were 247.8 nm and 297 nm, where the absorbance difference for DUL at these two wavelengths was equal to zero. Method (C) is the mean centering of ratio spectra spectrophotometric (MCR) method, which depends on measuring the mean centered values of ratio spectra of both DUL and 1-Naphthol at 226 nm.

These methods were validated and agreed with the requirements of ICH guidelines with respect to linearity, accuracy, precision and selectivity.

The results indicate the ability of developed methods to be used for routine quality control analysis of DUL in bulk and pharmaceutical formulations in the presence of its potential impurity 1-Naphthol.
The results indicate the ability of developed methods to be used for routine quality control analysis of DUL in bulk and pharmaceutical formulations in the presence of its potential impurity 1-Naphthol.
Aflatoxin (AF) contamination is one of the major regulatory concerns for animal feed. As feed is a complex analytical matrix, validated methods on AFs in feed are scanty. The available methods involve a derivatization step before AF analysis by high-performance liquid chromatography (HPLC) with fluorescence detection (FLD). The aim of this study was thus to develop and validate a simple and rapid method for direct analysis of AFs (AFB1, AFB2, AFG1, AFG2) in a range of animal feed matrices.

Feed samples were extracted with 80% methanol, followed by dilution with water and immmunoaffinity column cleanup. AFs were estimated using an ultra-high performance liquid chromatography (UHPLC) instrument. Use of a large volume flow cell in FLD allowed direct analysis of all AFs with high sensitivity. The method was thoroughly validated in a range of feed matrices.

This sample preparation workflow minimized co-extractives, along with matrix interferences. In pigeon pea husk feed, the method provided a limit of quantization.
The LuciPac A3 Surface Hygiene Monitoring System based on the detection of total adenylate, ATP+ADP+AMP (A3), has been developed by Kikkoman Biochemifa.

This A3 swabbing assay kit was validated for Performance Tested MethodsSM (PTM) certification.

The LuciPac A3 Surface Hygiene Monitoring System was evaluated for limit of detection (LOD) for each adenylate with pure analyte solutions, detection of food residues and microbial residues on stainless steel surfaces, interference by disinfectants, and selectivity of the method response.

Pure analyte studies performed by the method developer and the independent laboratory showed good linearity (R2 > 0.9854) and repeatability precision (RSDr < 20% for ≥2.5 fmol/assay). The LOD values for each adenylate were around 10 relative light units or 2.5 fmol/assay. The repeatability precision in the method developer laboratory for the matrix study (raw chicken breast, sliced deli ham, orange juice, yogurt, and apple pie) and the microbial study (Cronobacter sakazakii, Lactobacillus acidophilus, and Saccharomyces cerevisiae) were 8-30% and 10-35%, respectively.
Ophiopogonis radix and Liriopes radix are well known for the treatment of dry coughs and phthisis. Liriopes radix is occasionally used as a substitute for Ophiopogonis radix in various prescriptions due to the extremely similar pharmacological activities and clinical efficacies, but they are regarded as two different remedies in the Chinese Pharmacopoeia. Accordingly, the establishment of a reliable analytical approach for the discrimination and quality evaluation of Ophiopogonis and Liriopes is required. To establish a simple, accurate, and reliable method that can simultaneously determine multiple components in Ophiopogonis radix and Liriopes radix. To comprehensively compare the chemical compositions of the two herbs and find markers for discrimination and quality assessments. An HPLC-ESI-triple quadrupole (QQQ)-MS/MS method was developed for simultaneous characterization and quantification of chemical components in the two herbs. The results were further analyzed by PLS discriminant analysis to provadix by using HPLC-QQQ-MS/MS in positive ion mode, as well as the quality control study. Soleris®Enterobacteriaceae is a growth-based, automated method for detection of Enterobacteriaceae in food. A study was conducted to validate the Soleris method for detection of Enterobacteriaceae in select foods (pasteurized milk, yogurt, mozzarella cheese, ice cream, dried milk, pasteurized liquid egg, frozen cooked chicken, deli ham, lettuce, and dry dog food) at a threshold of ≥ 10 CFU/g of product. Inclusivity and exclusivity of the Soleris method were assessed by testing 55 and 38 target and non-target bacterial strains, respectively. Matrix testing was performed with one naturally contaminated and nine inoculated foods. Efficacy of the Soleris method was compared to that of the ISO 21528-22017 direct plating reference method using probability of detection analysis. Independent laboratory testing was conducted to verify method performance in two matrixes (yogurt and deli ham). Method robustness, stability, and lot-to-lot consistency of the Soleris reagents were also assessed. Inclusivity of the Soleris test was 91% and exclusivity was 100%. In matrix testing, there were no significant differences in the number of positive results obtained with the Soleris and reference methods for any of the matrixes examined. Overall, of 370 test portions, there were 176 positive results by the Soleris method and 177 positive results by the reference procedure. Soleris Enterobacteriaceae is an effective method for detection of Enterobacteriaceae in the foods evaluated, with performance equivalent to that of the ISO 21528-22017 reference method. The Soleris method offers the advantages of labor savings and results within 18 h. The Soleris method offers the advantages of labor savings and results within 18 h. Duloxetine hydrochloride (DUL) is a drug used to treat depression and anxiety. 1-Naphthol is a potential toxic impurity of DUL, as it causes hepatotoxicity in humans, and it is harmful to aquatic life. Three simple, selective, rapid, accurate and precise methods were developed and validated according to International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision and selectivity for analysis of duloxetine hydrochloride (DUL) in the presence of its potential toxic impurity 1-Naphthol in different laboratory-prepared mixtures and pharmaceutical formulations. Method (A) is the first derivative of the ratio spectra spectrophotometric (1DD) method which allows determination of DUL at 251 nm and 1-Naphthol at 305.2 nm without interference from each other. https://www.selleckchem.com/products/s-2-hydroxysuccinic-acid.html Method B (dual wavelength) means that two different wavelengths were chosen to each drug, where the absorbance difference at these two wavelengths is equal to zero to the second drug. The chosen two wavelengths for DUL were 221.4 nm and 235.6, where the absorbance difference for 1-naphthol at these two wavelengths was equal to zero. While the chosen wavelengths for 1-naphthol were 247.8 nm and 297 nm, where the absorbance difference for DUL at these two wavelengths was equal to zero. Method (C) is the mean centering of ratio spectra spectrophotometric (MCR) method, which depends on measuring the mean centered values of ratio spectra of both DUL and 1-Naphthol at 226 nm. These methods were validated and agreed with the requirements of ICH guidelines with respect to linearity, accuracy, precision and selectivity. The results indicate the ability of developed methods to be used for routine quality control analysis of DUL in bulk and pharmaceutical formulations in the presence of its potential impurity 1-Naphthol. The results indicate the ability of developed methods to be used for routine quality control analysis of DUL in bulk and pharmaceutical formulations in the presence of its potential impurity 1-Naphthol. Aflatoxin (AF) contamination is one of the major regulatory concerns for animal feed. As feed is a complex analytical matrix, validated methods on AFs in feed are scanty. The available methods involve a derivatization step before AF analysis by high-performance liquid chromatography (HPLC) with fluorescence detection (FLD). The aim of this study was thus to develop and validate a simple and rapid method for direct analysis of AFs (AFB1, AFB2, AFG1, AFG2) in a range of animal feed matrices. Feed samples were extracted with 80% methanol, followed by dilution with water and immmunoaffinity column cleanup. AFs were estimated using an ultra-high performance liquid chromatography (UHPLC) instrument. Use of a large volume flow cell in FLD allowed direct analysis of all AFs with high sensitivity. The method was thoroughly validated in a range of feed matrices. This sample preparation workflow minimized co-extractives, along with matrix interferences. In pigeon pea husk feed, the method provided a limit of quantization. The LuciPac A3 Surface Hygiene Monitoring System based on the detection of total adenylate, ATP+ADP+AMP (A3), has been developed by Kikkoman Biochemifa. This A3 swabbing assay kit was validated for Performance Tested MethodsSM (PTM) certification. The LuciPac A3 Surface Hygiene Monitoring System was evaluated for limit of detection (LOD) for each adenylate with pure analyte solutions, detection of food residues and microbial residues on stainless steel surfaces, interference by disinfectants, and selectivity of the method response. Pure analyte studies performed by the method developer and the independent laboratory showed good linearity (R2 > 0.9854) and repeatability precision (RSDr < 20% for ≥2.5 fmol/assay). The LOD values for each adenylate were around 10 relative light units or 2.5 fmol/assay. The repeatability precision in the method developer laboratory for the matrix study (raw chicken breast, sliced deli ham, orange juice, yogurt, and apple pie) and the microbial study (Cronobacter sakazakii, Lactobacillus acidophilus, and Saccharomyces cerevisiae) were 8-30% and 10-35%, respectively.
0 Comentários 0 Compartilhamentos 57 Visualizações 0 Anterior
Patrocinado