csPCa diagnosis rates in conventional TZ score 3 nodules. CLINICAL IMPACT. This study validates the DWI upgrade rule introduced in PI-RADS v2.1 for atypical nodules, which showed significant prostate cancer detection rates at targeted biopsy similar to those of conventional T2-weighted MRI TZ score 3 nodules.BACKGROUND. CT attenuation thresholds that accurately distinguish enostoses from untreated osteoblastic metastases have been published. In the Mayo Clinic practices, these thresholds have been applied more broadly to distinguish benign sclerotic bone lesions other than enostoses from osteoblastic metastases. OBJECTIVE. The purpose of this article is to determine if CT attenuation thresholds allow the distinguishing of benign sclerotic bone lesions from osteoblastic metastases in patients undergoing bone biopsy. METHODS. A retrospective search was conducted to identify sclerotic lesions described on CT between October 7, 1998, and July 15, 2018, that underwent subsequent biopsy. Two musculoskeletal radiologists recorded lesions' maximum and mean attenuation. Using previously published attenuation thresholds, sensitivity and specificity for differentiating benign sclerotic lesions from osteoblastic metastases were calculated. ROC curve analysis was performed to determine if more appropriate attenuation thresholation and 0.918 for mean attenuation. CONCLUSION. https://www.selleckchem.com/products/crenolanib-cp-868596.html Published attenuation thresholds for distinguishing enostoses from osteoblastic metastases had slightly decreased specificity and markedly decreased sensitivity when applied to the differentiation of benign sclerotic lesions from osteoblastic metastases in our sample of biopsy-proven lesions. ROC analysis showed no high-performing attenuation threshold alternative. CLINICAL IMPACT. Published CT attenuation thresholds intended for distinguishing enostoses from osteoblastic metastases should not be used more broadly. More accurate alternative thresholds could not be derived.BACKGROUND. Obesity is a worldwide problem that impacts patient health as well as the morbidity associated with surgical procedures. Thus, patients with morbid obesity may not be suitable candidates for curative surgery. For this patient population, thermal ablation may be an effective alternative to nephrectomy. OBJECTIVE. The purpose of this study was to determine the feasibility, oncologic outcomes, and survival of patients with morbid obesity and renal cell carcinoma treated with thermal ablation. MATERIALS AND METHODS. A retrospective analysis was performed of 107 patients treated with CT-guided renal ablation for clinical T1 renal cell carcinoma between February 2005 and December 2017. Patients were stratified into two cohorts on body mass index of ≥ 40 kg/m2 (morbidly obese) and body mass index of 18.5-24.9 kg/m2 (normal weight). Anesthetic and radiation dosages, procedure time, residual disease, and local recurrence, and adverse events were analyzed between the two groups. Kaplan-Meier statistics were in patients with morbid obesity.OBJECTIVE. The purpose of this study was to evaluate radiation dose, effective dose, and image quality of different low-dose abdominal CT protocols in a ***** model and an anthropomorphic phantom using a third-generation dual-source CT scanner. MATERIALS AND METHODS. Four different abdominal low-dose protocols were established using a ***** model and were regarded as diagnostic by two experienced radiologists on the basis of clarity and sharpness of anatomic structures. General image conditions such as noise and spatial resolution as well as diagnostic acceptability and artifacts were evaluated. Objective image quality was determined by measuring signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in different anatomic locations. To evaluate the effective dose, thermoluminescent dosimeter (TLD) measurements were repeated in a phantom. RESULTS. Diagnostic acceptability, spatial resolution, and noise were rated as optimal in all four protocols, which were therefore regarded as diagnostic. We found no statistically significant differences in SNR or CNR for the four low-dose protocols. Effective dose determined from the phantom measurements did not exceed 0.33 mSv for any protocol. Overall evaluation of the 86 TLD measurements for the four low-dose protocols revealed a statistically significant difference in radiation dose (p less then 0.0001), showing that the dual-source protocol had the lowest radiation dose. CONCLUSION. Submillisievert abdominal CT is feasible with good image quality and doses even lower than conventional abdominal radiography. Our dual-source protocol achieved the lowest dose, which further shows that dual-source imaging is possible in the submillisievert range without additional dose.OBJECTIVE. The purpose of this study was to assess the MR enterographic features of primary small intestinal lymphoma (PSIL) and compare them with active Crohn disease (CD) presenting with severe (≥ 10 mm) mural thickening of the small bowel. MATERIALS AND METHODS. This retrospective study included 15 patients with pathologically proven PSIL and 15 patients with active inflammatory CD with severe mural thickening. Various morphologic, enhancement, and diffusion parameters were compared between the two groups at MR enterography. The ratios of the upstream to involved luminal diameter and mural thickness to luminal diameter in the involved segment were calculated. An attempt was made to define a predictive model (morphologic score) for discriminating PSIL from CD with severe mural thickening. RESULTS. Patients with PSIL were more likely than those with CD to have unifocal disease (66.7% vs 20.0%, p = 0.025), circumferential involvement (86.7% vs 26.7%, p less then 0.001), luminal dilatation (60.0% vs 7.0%, p ower ratios of upstream to involved luminal diameter and mural thickness to involved luminal diameter in PSIL.OBJECTIVE. The objective of our study was to explore the relationship between a CT-based radiomics score and grade of nonfunctioning pancreatic neuroendocrine tumors (PNETs) and to evaluate the ability of a calculated CT radiomics score to distinguish between grade 1 and grade 2 nonfunctioning PNETs. MATERIALS AND METHODS. This retrospective study assessed 102 patients with surgically resected, pathologically confirmed nonfunctioning PNETs who underwent **** from January 2014 to December 2017. Radiomic methods were used to extract features from portal venous phase CT scans, and the least absolute shrinkage and selection operator (LASSO) method was used to select the features. Multivariate logistic regression models were used to analyze the association between the CT radiomics score and nonfunctioning PNET grades. The performance of the CT radiomics score was assessed on the basis of its discriminative ability and clinical usefulness. RESULTS. The CT radiomics score, which consisted of four selected features, was significantly associated with nonfunctioning PNET grades.
csPCa diagnosis rates in conventional TZ score 3 nodules. CLINICAL IMPACT. This study validates the DWI upgrade rule introduced in PI-RADS v2.1 for atypical nodules, which showed significant prostate cancer detection rates at targeted biopsy similar to those of conventional T2-weighted MRI TZ score 3 nodules.BACKGROUND. CT attenuation thresholds that accurately distinguish enostoses from untreated osteoblastic metastases have been published. In the Mayo Clinic practices, these thresholds have been applied more broadly to distinguish benign sclerotic bone lesions other than enostoses from osteoblastic metastases. OBJECTIVE. The purpose of this article is to determine if CT attenuation thresholds allow the distinguishing of benign sclerotic bone lesions from osteoblastic metastases in patients undergoing bone biopsy. METHODS. A retrospective search was conducted to identify sclerotic lesions described on CT between October 7, 1998, and July 15, 2018, that underwent subsequent biopsy. Two musculoskeletal radiologists recorded lesions' maximum and mean attenuation. Using previously published attenuation thresholds, sensitivity and specificity for differentiating benign sclerotic lesions from osteoblastic metastases were calculated. ROC curve analysis was performed to determine if more appropriate attenuation thresholation and 0.918 for mean attenuation. CONCLUSION. https://www.selleckchem.com/products/crenolanib-cp-868596.html Published attenuation thresholds for distinguishing enostoses from osteoblastic metastases had slightly decreased specificity and markedly decreased sensitivity when applied to the differentiation of benign sclerotic lesions from osteoblastic metastases in our sample of biopsy-proven lesions. ROC analysis showed no high-performing attenuation threshold alternative. CLINICAL IMPACT. Published CT attenuation thresholds intended for distinguishing enostoses from osteoblastic metastases should not be used more broadly. More accurate alternative thresholds could not be derived.BACKGROUND. Obesity is a worldwide problem that impacts patient health as well as the morbidity associated with surgical procedures. Thus, patients with morbid obesity may not be suitable candidates for curative surgery. For this patient population, thermal ablation may be an effective alternative to nephrectomy. OBJECTIVE. The purpose of this study was to determine the feasibility, oncologic outcomes, and survival of patients with morbid obesity and renal cell carcinoma treated with thermal ablation. MATERIALS AND METHODS. A retrospective analysis was performed of 107 patients treated with CT-guided renal ablation for clinical T1 renal cell carcinoma between February 2005 and December 2017. Patients were stratified into two cohorts on body mass index of ≥ 40 kg/m2 (morbidly obese) and body mass index of 18.5-24.9 kg/m2 (normal weight). Anesthetic and radiation dosages, procedure time, residual disease, and local recurrence, and adverse events were analyzed between the two groups. Kaplan-Meier statistics were in patients with morbid obesity.OBJECTIVE. The purpose of this study was to evaluate radiation dose, effective dose, and image quality of different low-dose abdominal CT protocols in a swine model and an anthropomorphic phantom using a third-generation dual-source CT scanner. MATERIALS AND METHODS. Four different abdominal low-dose protocols were established using a swine model and were regarded as diagnostic by two experienced radiologists on the basis of clarity and sharpness of anatomic structures. General image conditions such as noise and spatial resolution as well as diagnostic acceptability and artifacts were evaluated. Objective image quality was determined by measuring signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in different anatomic locations. To evaluate the effective dose, thermoluminescent dosimeter (TLD) measurements were repeated in a phantom. RESULTS. Diagnostic acceptability, spatial resolution, and noise were rated as optimal in all four protocols, which were therefore regarded as diagnostic. We found no statistically significant differences in SNR or CNR for the four low-dose protocols. Effective dose determined from the phantom measurements did not exceed 0.33 mSv for any protocol. Overall evaluation of the 86 TLD measurements for the four low-dose protocols revealed a statistically significant difference in radiation dose (p less then 0.0001), showing that the dual-source protocol had the lowest radiation dose. CONCLUSION. Submillisievert abdominal CT is feasible with good image quality and doses even lower than conventional abdominal radiography. Our dual-source protocol achieved the lowest dose, which further shows that dual-source imaging is possible in the submillisievert range without additional dose.OBJECTIVE. The purpose of this study was to assess the MR enterographic features of primary small intestinal lymphoma (PSIL) and compare them with active Crohn disease (CD) presenting with severe (≥ 10 mm) mural thickening of the small bowel. MATERIALS AND METHODS. This retrospective study included 15 patients with pathologically proven PSIL and 15 patients with active inflammatory CD with severe mural thickening. Various morphologic, enhancement, and diffusion parameters were compared between the two groups at MR enterography. The ratios of the upstream to involved luminal diameter and mural thickness to luminal diameter in the involved segment were calculated. An attempt was made to define a predictive model (morphologic score) for discriminating PSIL from CD with severe mural thickening. RESULTS. Patients with PSIL were more likely than those with CD to have unifocal disease (66.7% vs 20.0%, p = 0.025), circumferential involvement (86.7% vs 26.7%, p less then 0.001), luminal dilatation (60.0% vs 7.0%, p ower ratios of upstream to involved luminal diameter and mural thickness to involved luminal diameter in PSIL.OBJECTIVE. The objective of our study was to explore the relationship between a CT-based radiomics score and grade of nonfunctioning pancreatic neuroendocrine tumors (PNETs) and to evaluate the ability of a calculated CT radiomics score to distinguish between grade 1 and grade 2 nonfunctioning PNETs. MATERIALS AND METHODS. This retrospective study assessed 102 patients with surgically resected, pathologically confirmed nonfunctioning PNETs who underwent MDCT from January 2014 to December 2017. Radiomic methods were used to extract features from portal venous phase CT scans, and the least absolute shrinkage and selection operator (LASSO) method was used to select the features. Multivariate logistic regression models were used to analyze the association between the CT radiomics score and nonfunctioning PNET grades. The performance of the CT radiomics score was assessed on the basis of its discriminative ability and clinical usefulness. RESULTS. The CT radiomics score, which consisted of four selected features, was significantly associated with nonfunctioning PNET grades.
0 Comments
0 Shares
20 Views
0 Reviews
